Sprinkler Monitoring for Commercial Buildings in Illinois

Your sprinkler system can't call for help by itself. We connect its waterflow and valve switches to our UL-listed central station, so a fire, a closed valve, or a freezing pipe gets reported the moment it happens, day or night.

Since 1982

40+ years protecting Illinois properties

UL listed

Alarm provider and central station

Bosch authorized

Security dealer

24/7 monitoring

Live operators, every night of the year

What sprinkler monitoring actually has to do

Sprinkler monitoring watches two things. Water moving through the pipes, which usually means a fire. And anything that would stop water from moving when you need it.

The second part gets ignored.

One of the most common reasons sprinklers fail in a real fire is a valve someone closed and forgot to reopen. A contractor shuts it during a repair. A tenant closes it to stop a leak. Months later, the system looks fine but can't flow. Monitoring catches that the minute the valve moves.

Who we monitor sprinkler systems for

  • Warehouses and distribution centers with large sprinkler zones
  • Office and apartment buildings required to monitor by local code
  • Restaurants and retail spaces in multi-tenant buildings
  • Manufacturers with dry or pre-action systems in unheated areas
  • Property owners whose insurer requires central station monitoring

Monitoring your fire alarm too? See our 24/7 monitoring services and fire protection systems pages.

What we monitor on your sprinkler system

Every sprinkler system has a few points that tell the whole story. We connect each one to our station.

Waterflow switches

Detect water moving through the pipes and send a fire alarm signal, so the fire department is called right away.

Signals: fire alarm

Valve tamper switches

Report when a control valve is partly or fully closed, so a shut system doesn't go unnoticed.

Signals: supervisory

Low air pressure

Watch air pressure on dry and pre-action systems, where a drop can mean a leak or a failing compressor.

Signals: supervisory

Low temperature sensors

Alert us when a valve room or unheated area gets cold enough to freeze pipes.

Signals: supervisory

Fire pump supervision

Report pump running, power loss, and phase problems on buildings with a fire pump.

Signals: supervisory and trouble

Panel and power

Watch the panel that monitors your sprinkler points for power loss, low battery, and wiring faults.

Signals: trouble

What happens when a sprinkler opens at 3:05 a.m.

Here's how a typical overnight fire plays out at a warehouse with ASI sprinkler monitoring.

3:05:00

Heat opens a sprinkler head

A fire near a rack of stock heats a sprinkler head until it opens and water starts flowing.

3:05:45

Waterflow switch trips

After a short built-in delay that filters out pressure surges, the flow switch sends an alarm to the panel.

3:05:48

Our operator gets the signal

The alarm reaches our central station with your address, building notes, and which zone is flowing.

3:06:15

Fire department dispatched

The operator dispatches the fire department to your address, then starts working through your call list.

3:07:00

Owner and key holder notified

You and your contacts are called so someone can meet the fire department and shut water off once it's safe.

Wet, dry, or pre-action: what gets monitored on each?

The type of sprinkler system you have changes what we watch. Here's how they compare.

We'll confirm your system type and monitoring points during a site visit.
System type Where it's used What we monitor Watch for
Wet pipeHeated offices, stores, apartmentsWaterflow, valve tamper, panel powerClosed valves after repairs
Dry pipeUnheated warehouses, garages, docksWaterflow, tamper, air pressure, low temperatureAir leaks and cold valve rooms
Pre-actionServer rooms, archives, museumsWaterflow, tamper, air pressure, detection circuitsDetection and valve faults
fire sprinkler monitoring

A closed valve is a silent failure

Nothing beeps when a sprinkler valve is closed. The system just sits there, unable to flow, until a fire proves it. Here's how we make sure that never happens quietly.

  • !
    Tamper alerts: we know the moment a valve starts to close
  • !
    Follow-up calls: our operators call until someone confirms why
  • !
    Contractor procedures: we help you log planned shutdowns
  • !
    Freeze warnings: low temperature alerts before pipes burst
  • !
    Regular testing: we test flow and tamper signals on schedule

How setup works

Most sprinkler systems can be connected to monitoring without touching the pipes.

1

Site survey

We locate your risers, valves, and switches and check what's already wired.

2

Written proposal

You get a list of every monitored point and the monitoring plan, with a fixed price.

3

Connect and test

We wire each switch to a monitoring panel and test every signal with our station.

4

Ongoing testing

We test your flow and tamper signals on schedule and keep the records for you.

Sprinkler monitoring FAQs

Is sprinkler monitoring required?

In many buildings, yes. Local fire codes and insurers often require sprinkler systems to be monitored by a central station. Your fire department sets the rules for your building, and we'll help you confirm what applies.

What's the difference between a waterflow alarm and a supervisory signal?

A waterflow alarm means water is moving, usually from a fire, and the fire department is called. A supervisory signal means something needs attention, like a closed valve or low air pressure, and we call your contacts.

What happens if a contractor needs to shut a valve?

Call us before the work starts. We note the planned shutdown on your account, and our operators follow up if the valve isn't reopened when the work should be done.

Can you monitor a sprinkler system someone else installed?

Yes. We can connect most existing sprinkler switches to our central station, often by reusing the panel or wiring already in place.

Will a pressure surge cause a false alarm?

Waterflow switches have a short built-in delay that filters out normal pressure surges from the water supply. Real flow lasts longer than the delay and triggers the alarm.

How often are monitored sprinkler signals tested?

Flow and tamper signals are tested on a schedule set by NFPA 25 and your local fire code. We handle the testing and keep the records.